Attenuators

Attenuators

It is constructed from cylindrical cavity resonator with a variable short circuit termination. The shorting plunger is used to change the resonance frequency of the cavity by changing the cavity length. DRF measures the frequency directly. It is particularly useful when measuring frequency differences of small changes.

Variable attenuators

These attenuators provide continuous attenuation power upto 20 dB.

Specifications

Model
Band
Freq. Range(GHz)
Waveguide Attenuation (dB) VSWR Accuracy
SA 101 S 2.60-3.95 WR-284 0-20 1.1 +/-0.5 dB
CA 101 C 3.95-5.85 WR-229 0-20 1.1 +/-0.5 dB
JA 101 J 5.85-8.20 WR-137 0-20 1.1 +/-0.5 dB
XA 101 X 8.20-12.40 WR-90 0-20 1.1 +/-0.5 dB
KuA 101 Ku 12.40-18.00 WR-62 0-20 1.1 +/-0.5 dB
KA 101 K 18.00-26.50 WR-42 0-20 1.1 +/-0.5 dB
Fixed attenuators

The attenuators provide fixed attenuation of 3,6,10,20 dB

Specifications

Model
Band
Freq. Range(GHz)
Waveguide Attenuation (dB) VSWR Accuracy
SA 102 S 2.60-3.95 WR-284 3,6,10,20 1.08 +/-0.5 dB
CA 102 C 3.95-5.85 WR-229 3,6,10,20 1.08 +/-0.5 dB
JA 102 J 5.85-8.20 WR-137 3,6,10,20 1.08 +/-0.5 dB
XA 101 X 8.20-12.40 WR-90 3,6,10,20 1.1 +/-0.5 dB
KuA 102 Ku 12.40-18.00 WR-62 3,6,10,20 1.08 +/-0.5 dB
KA 102 K 18.00-26.50 WR-42 3,6,10,20 1.08 +/-0.5 dB